Tests and validation

Validating water-sensitive paper analysis by phone

We compared phone photos with 2400 DPI flatbed scans of the same papers, the laboratory reference, and simulated 22 capture conditions. The results and methodology are in the technical report.

11 of 11
photos in the same droplet class as the scanner
0.99
Lin's concordance for VMD
4.4%
median difference in VMD

Document

Technical validation report

The methodology, the papers analyzed and the results in a single file, ready to share with your technical team. The report is in Portuguese.

  • Comparison with a 2400 DPI laboratory scanner
  • Effect of resolution, distance, light and focus
  • Comparison with a commercial field tool
  • VMD, Dv0.9, droplet density and coverage
  • Recommendations for photographing the paper

spraydex-validacao.pdf

PDF · 66 pages

Download report

Results

What the study found

The study used ten water-sensitive papers, from fine, dense droplets to ultra coarse, sparse droplets, in 11 photos taken with an iPhone 15 Pro.

Comparison with the scanner

The photo landed in the same droplet class as the scanner in 11 of 11 cases. The median difference in VMD was 4.4%, with no detectable systematic bias.

Density and coverage

Lin's concordance with the scanner was 0.994 for density and 0.966 for coverage. The decision on thresholds of 20 to 70 droplets/cm² was the same in all 11 cases.

Simpler cameras

With resolution equivalent to 8 and 5 megapixel cameras, simulated from the photos, the class stayed the same as the scanner. VMD varied by at most 4.9%.

Light, shadow and compression

Simulated changes in lighting, partial shadow, noise and compression changed VMD by at most 2.4%, with no change in droplet class.

Distance and focus

Up to 1.4 times the original distance, VMD varied by at most 3.3%. With slight and moderate blur, the droplet class held.

Commercial field tool

In seven papers from a field trial, the class matched in 5, and the other two were within 1.5% of the class boundary. On dense papers, the median difference in VMD was 2.6%.

How to read these results

The study was carried out by the Spraydex team. Photo and scanner went through the same analysis engine, which isolates the effect of capture. Laser diffraction was not used as a reference because it measures the droplet spectrum at the nozzle, not the stain on the paper.